Activation
Loop 1: presence for activation.
Price on request
Indicative public prices excl. VAT — Please contact us to confirm price, availability and configuration.
Parking, ticketing and vehicle entrances: configurable detection to coordinate several devices, with Control Access.

An alternative to a buried induction loop where the installation allows.
App-based teach-in and settings: target, zone and direction of travel.
Signals for the barrier, ticketing or an external number-plate reader. EVOLOOP does not read plates.
Loop 1: presence for activation.
Loop 2: detection within the protection zone.
Loop 3: presence for acknowledgement.
60 GHz FMCW radar · range up to 7 m · 140° opening · IP65 · consumption < 3 W.
Physical outputs: 2 electronic relays + 1 relay. BEA wiring example: check output assignments and logic in the user guide and against the control board.
EN 12453 type D protection supplements type C force limitation. Compliance of the complete installed system must still be checked.
FMCW activation and presence radar for barriers. Three configurable virtual zones, up to 7 m and 140° according to the manufacturer. Level D complements level C force limitation.
For a suitable quote: intended function, detection zone, mounting height, power supply and control interface.
Safety: level D detection complements level C force limitation measures. Compliance depends on the complete installation.
Configuration: assign the three virtual zones independently, specify targets and movement direction. Teach-in and settings use the manufacturer's app.
FMCW activation and presence radar for barriers. Three configurable virtual zones, up to 7 m and 140° according to the manufacturer. Type D complements type C force limitation.
Links reproduced from the supplied PDF; their online availability has not been checked for this delivery. The document and certificates for the exact model supplement the information above.
Source: Control Access Catalogue 2027/2028, working edition V2, page 104. Specifications are taken from this document; product references, versions, compatibility and availability remain to be confirmed when preparing the quotation. No prices have been added.
FMCW activation and presence radar for barriers. Three configurable virtual zones, up to 7 m and 140° according to the manufacturer. Level D complements level C force limitation.
Product references and versions should be confirmed in the linked documentation.
EVOLOOP is BEA's radar for opening, presence and protection at automatic barriers. Its virtual loops replace the in-ground inductive loop and are configured for site traffic. Control Access helps you choose placement, interfaces and the configuration to be quoted.
| Specification | Manufacturer data |
|---|---|
| Technology | FMCW radar, MoWa Inside; 60 GHz microwave. |
| Virtual loops | Up to 3 independently configurable loops. |
| Stated maximum detection field | Up to 7 m, depending on application and setting. |
| Radar field of view | 140° opening; 40° elevation. |
| Mounting height | Between 30 and 70 cm above the ground; position the detector as low as possible within this range. |
| Antenna orientation | Adjustment from −20° to +20°. |
| Power | 12 to 30 V DC ±10% or 12 to 24 V AC ±10%. |
| Maximum consumption | Below 3 W. |
| Interfaces | Two electronic relays and one relay; optocoupled test input. |
| Response time | Typical 100 ms; maximum 250 ms. |
| Enclosure protection | IP65 according to IEC/EN 60529. |
| Temperature and humidity | −25 °C to +55 °C; maximum +50 °C with AC supply. Relative humidity from 0 to 95%, non-condensing. |
| Dimensions | 50 × 150 × 68 mm. |
| Configuration and cable | EVOLOOP mobile app via Bluetooth; standard 3 m cable. |
Values and conditions published by BEA. BEA instructions p. 15 ↗ · BEA data sheet p. 2 ↗
Additional type D protection — BEA describes a level D protection function according to EN 12453. It must complement a system providing level C barrier force limitation; EVOLOOP alone does not guarantee installation compliance. BEA manual p. 2 ↗
Position and coverage to be defined on site — For protection, the instructions require positioning no more than 50 cm from the boom. The field must cover the barrier length and be adjusted for protection on one or both sides. BEA instructions p. 2 ↗
Commissioning and tests — Installation and commissioning are reserved for a trained specialist. The device's test input and checks must follow the manual; it specifies a test before every movement and, if the test input is not used, a check at least every six months. BEA manual p. 2 ↗
Power supply and environment — Provide a supply ensuring the double insulation required by BEA. Keep the front clear, avoid metal parts in its immediate vicinity and keep the surface clean; do not clean directly with high-pressure equipment. BEA instructions p. 4 ↗
Equipping a car park or barrier entrance in Marseille or PACA? Send us the barrier type, passage width, expected traffic flows and available supply to prepare your quotation.
Manufacturer documents remain in their original language.