ASO · monitoring, transmission and industrial applications
Compare ELMON relays, inductive transmission systems, mats, bumpers, LISENS sensors and DRICO controllers. Switching modules not intended for safety functions are identified as such. Check interfaces and installation conditions for each reference.
This page brings together Control Access Distribution solutions. Each reference retains its own product page and documentation. Choose suitable references before adding them to your quotation request.
Illustration from the sheet ‘ELMON relay 31-31 · tactile sensor monitoring’. Official ASO image associated with ELMON relay 31-31. Contents and options depend on the manufacturer's sheet. Source ↗Illustration from the sheet ‘ELMON relay 32-242 · tactile sensor monitoring’. Official ASO image associated with ELMON relay 32-242. Contents and options depend on the manufacturer's sheet. Source ↗Illustration from the sheet ‘ELMON relay 35-32 · tactile sensor monitoring’. Official ASO image associated with ELMON relay 35-32. Contents and options depend on the manufacturer's sheet. Source ↗
Single-channel monitoring relay in a surface-mount housing. It evaluates a pressure-sensitive sensor with 8,2 kΩ termination and has one relay contact. ASO publishes a 230 V or 24 V AC/DC supply; choose the connection and test according to the instructions.
Two-channel monitoring relay for DIN-rail mounting and 24 V AC/DC power. It evaluates two sensor inputs with 8,2 kΩ termination and has redundant force-guided contacts. Validate sensor and controller connections according to the ASO manual.
Two-channel DIN-rail monitoring device, with two 8,2 kΩ sensor inputs and two relay contacts. It is offered with 230 V or 24 V AC/DC power. Sensor, test logic and wiring selection depends on the application.
Single-channel DIN rail monitoring relay for evaluating a contact sensor with 8,2 kΩ termination. It has a redundant force-guided contact. Select supply and test functions according to the instructions and the installation's control architecture.
Inductive transmission set for moving safety edges on sliding gates, with 8,2 kΩ termination monitoring. It includes the DIN-rail unit, fixed and moving cores, a 20 m sheathed steel cable and tensioning device. Unit power supply: 24 V AC/DC.
Inductive transmission assembly for moving safety edges, with surface-mount housing unit, fixed and moving cores, 20 m coated steel cable and tensioning device. Transmission is battery-free; the unit is powered by 230 V or 24 V AC/DC depending on the connection.
Configurable contact mat assembly for monitoring a machine work area. Pressure on the mat triggers a signal to be processed by suitable safety electronics. ASO states polyurethane covering and a 24 V, 100 mA circuit; dimensions and assembly to be defined.
ASO pressure-sensitive bumper for outdoor use and ground support equipment (GSE). It combines a deformable volume with a detection contact for areas requiring a longer compression stroke. Dimensions, force, mounting and electronics must suit the movement being monitored.
Radar assembly for barriers comprising a sensor and an evaluation unit. It detects objects and vehicles within a configurable field to control passage. The data sheet states a 13 m detection distance; placement, settings, software and connection depend on the site.
ASO control for sliding gate, shutter and sectional door drives, described for 400 V three-phase and 230 V single-phase motors. It forms part of a defined control and safety architecture. Check motor type, limit switches and sensors before selection.
Single-channel DIN-rail module for reading a tactile device with an 8.2 kΩ terminal resistance and providing a relay contact. ASO explicitly states that this model is not intended for safety systems.
Dual-channel evaluation relay in a wall-mounted enclosure for two 8.2 kΩ tactile signal transmitters. Two redundant forcibly guided relay outputs pass their states to a machine or gate controller.
DIN-rail relay that evaluates two 8.2 kΩ signal transmitters and provides one common relay contact. It integrates with a controller that performs the ASO test required for the category 2 architecture.
24 V DC dual-channel DIN-rail evaluation module for two 8.2 kΩ signal transmitters. Its two semiconductor outputs connect to a controller compatible with this interface.
Single-channel evaluation relay in a wall-mounted enclosure for one 8.2 kΩ tactile signal transmitter. It provides a redundant forcibly guided relay output, with published supply options of 230 V AC or 24 V AC/DC.
Dual-channel DIN-rail evaluation relay for two 8.2 kΩ signal transmitters, with two redundant forcibly guided relay contacts. It accepts an 85–265 V AC mains supply or a 24 V AC/DC supply.
Battery-free transmission set between a moving 8.2 kΩ contact edge and the fixed controller of a sliding gate. The ASO page lists the version R module with test input and display, moving SPK 54 S coil core and cable mounting assembly.
Evaluation board for the ELMON inductive signal transmission system, manufacturer model 70-755, article 1203-0020. This unenclosed version is listed for 24 V DC supply and must be selected together with the other system components and interfaces.
Evaluation board for the ELMON inductive signal transmission system, manufacturer model 70-757, article 1402-0740. This unenclosed version is listed for 24 V DC supply and must be selected together with the other system components and interfaces.
Evaluation board for the ELMON inductive signal transmission system, manufacturer model 74-332, article 1206-0070. This unenclosed version is listed for 24 V AC/DC or 230 V AC ±10% supply and must be selected together with the other system components and interfaces.
ASO frequency converter controller for doors and gates, in FU A0101 version. Its three-phase 230 V motor output is rated at 4 A. A display and selection controls support setup and diagnostics, with inputs for command devices, limit switches and detection equipment.
ASO frequency converter controller for doors and gates, in FU A0102 version. Its three-phase 230 V motor output is rated at 10 A. A display and selection controls support setup and diagnostics, with inputs for command devices, limit switches and detection equipment.
ASO barrier radar set containing two sensors and one evaluation unit. Configurable fields support presence monitoring and activation zones, with Wi-Fi setup. This configuration handles two sensor positions through one evaluation unit.
LISENS radar sensor for contactless detection around a barrier, supplied without an evaluation unit. It joins a compatible LISENS scan system to configure presence and activation fields. This reference is the individual sensor for a defined configuration or system extension.
ASO tactile bumper for moving systems needing deformation travel and outdoor use. The 100-120 L/O combines an absorbing core and internal sensing element under an artificial leather cover. Its 100 × 120 mm section must be selected against the system’s actual stopping behaviour.
ASO safety contact bumper intended for collaborative robotics. Its deformable structure contains a sensing element that signals actuation to the evaluation electronics. Shape and integration must suit the exposed zones, robot movement and space required for stopping.
Tactile bumper with a foam core, aluminium carrier and NBR rubber cover. It serves machine or moving-system projects requiring contact detection with deformation travel. The black surface can receive yellow stripes according to the selected configuration.
ASO 14 mm safety mat with a aluminium checker plate surface for monitoring an accessible machine area. Pressure on the surface is detected and processed by suitable evaluation electronics. The ARB cover distinguishes this version from flexible-surface mats.
ASO 14 mm safety mat with a stainless steel tear plate surface for monitoring an accessible machine area. Pressure on the surface is detected and processed by suitable evaluation electronics. The TBV cover distinguishes this version from flexible-surface mats.
ASO 14 mm safety mat with a nubbed surface and integrated moulded ramp. It monitors an accessible machine area by detecting pressure, with suitable evaluation electronics. The ramp belongs to this T version and must be included in the floor footprint.