Keypad with flush-mounted stainless-steel trim and VIGIK reader, listed in ACIE documentation. The data sheet states 60 users, 12–24 V AC/DC supply and IP65 rating. Keys are polycarbonate or metal according to configuration; credential BA403-VI is to be supplied separately. Supply contents, availability and reader version to be specified in the quotation.
ACIE
ACIE offers access control solutions for homes, communal buildings and professional sites. Find priority selections of keypads with surface- or flush-mounted stainless steel surrounds, then the 3D-FACE biometric reader offered by ACIE, followed by other keypads, readers and equipment.
PDF catalogues
The PDF language is shown. Reading editions may retain the original document pages.
Keypads with stainless-steel covers, first.
Two complete VIGIK reader configurations and the configurable SU range: choose surface or flush mounting, relay count and suitable credentials.
Surface-mounted stainless-steel keypad with VIGIK reader, referenced in ACIE documentation. The sheet specifies 60 users, 12–24 V AC/DC power and rating IP65. Keys are polycarbonate or metal depending on configuration; credential BA403-VI must be provided separately. Supplied contents, availability and reader version must be specified in the quote.
Stainless-steel cover to be chosen with the basic keypad.
Optional SAB/EAB stainless-steel cover for mounting.
The biometric selection offered by ACIE.
The 3D-FACE facial reader presented in ACIE documentation is Hanvon branded. Consult its capacities and integration conditions.
Reference offered by ACIE · Hanvon brand.
Other ACIE keypads, readers and equipment.
Controls, credential readers, modules and power supplies remain accessible to complete your project.
Standalone family for 250 users, with two relays and 12-24 V AC/DC power supply. SUPM01 is not compatible with the stainless-steel cover specified for the other versions.
The finish and potting suit different environments. Confirm the exact reference: IP65 as standard, IP66 for the described potted version.
WDT versions transmit to a controller and do not directly replace a standalone device. Check Wiegand/DataClock, output format and power supply.
The DIN controllers shown manage 65 000 users and two reader inputs. Define the network architecture, access policy and backup power supply.
The radio protocol and credential reading method must match your security policy. Send a sample credential and the controller reference.
A selection for a door or access point without extensive supervision. Specify user numbers, code changes and event history requirements before choosing standalone or connected equipment.
Do not order a credential solely by its frequency. Format, encoding and programming permissions are part of compatibility.
An ANPR study requires distance, angle, lighting, speed and number plate countries. Define fallback modes and visitor handling with the site manager.
Include power supply, exit control and backup in the parts list. Other ACIE products are available on request.
Connected standalone set with remote electronics for managing entry and exit from a computer. The manufacturer offers Wi-Fi or RJ45 versions, with keypad or reader, and smartphone alerts when a door is forced or left open.
Keypad and Bluetooth reader for alarm and access control. It accepts 120 user codes of one to eight digits and offers three Bluetooth modes with the AC-BL and AC-BL TAG apps. Its relay can operate in on/off mode.
Standalone two-relay keypad combining code entry and hands-free reading of 868 MHz RF-SMART tags. It has backlit keys, 60 user codes and timed or maintained outputs, in a surface-mount aluminium housing.
Standalone proximity reader for managing up to 250 credentials in 125 kHz format. Its two relays can be timed or latched. Erasure and relay-assignment cards must be provided for programming, according to site equipment.
Compact standalone reader for one door or a small-capacity access point. Stores 30 credentials in 125 kHz format and provides one timed or maintained relay output. Its ABS enclosure is rated IP66 and powered by 12 V DC.
868 MHz hands-free reader for active tags, supplied with antenna and mounting accessories. It manages four timed or maintained relays and a site code. An optional antenna allows two-direction traffic operation to be assessed.
Standalone 868 MHz rolling code radio receiver with capacity for 800 remote controls. Its four relays can be timed or maintained. Visual and audible indicators assist operation; an additional antenna may be included according to site obstacles.
Reader combining 125 kHz and 13,56 MHz frequencies, with support for the HID 125 kHz format published by ACIE. Its Wiegand output is configurable from 26 to 58 bits. It has red/green visual signalling and a 12 to 24 V supply.
Keypad and reader for alarm and access control, rated IP65. ACIE lists support for several MIFARE technologies, including DESFire EV1 and EV2, and certain NFC credentials. Assess credential and controller selection with the installation.
Keypad with backlit metal keys and integrated 868 MHz RF-SMART reader. It provides tamper protection and visual and audible indicators. Its power supply accepts 12 or 24 V DC, and its IP65 rating allows exposed-environment installation to be assessed.
Two-column keypad for access control and alarm systems. The ACIE data sheet states Dataclock or 26/44-bit Wiegand communication, IP65 protection and dimensions of 172 × 47 × 29 mm. Controller and output format to be specified in the quotation.
Metal keypad with 125 kHz proximity reader, offered for standalone operation or Wiegand output. The official sheet specifies 1 000 users, one relay and three modes: code, credential, or code combined with credential. Power supply 12/24 V AC/DC and rating IP65.
Metal keypad and Bluetooth reader for ELA+ access control installations. The official datasheet describes remote electronics and remote control or hands-free uses with the AC-BL and AC-BL TAG applications. Controller contents and mobile compatibility must be specified in the quotation.
Keypad for ELA-EVOLUTION bus with remote electronics and 1 to 8-digit code entry. The manufacturer specifies a IP66 keypad measuring 110 × 85 × 22 mm, IP54 electronics and 12 V DC power supply. The centralised system configuration must be defined in the quote.
Backlit metal-key keypad for RS485-ELA bus, with built-in RF-SMART 868 MHz reader. The official page states 12/24 V DC supply, IP65 protection and tamper protection. Specify radio credentials and control unit according to site requirements.
RS485-ELA proximity reader for EVOLUTION system, using the 125 kHz EM format. The ACIE page states two timed or maintained relay outputs, IP65 protection and 12 V AC/DC supply. Any stainless-steel faceplates and enclosures are to be specified in the quotation.
Local unit for the EVOLUTION system, supplied without power supply. Presented in a housing with microswitch opening tamper protection, IP54 rating and 12/24 V AC or DC supply. Reader configuration and power requirements must be defined for the installation.
ELA+ system expansion with eight contact inputs and eight programmable relay outputs. The enclosure has opening tamper protection and rating IP54. The manufacturer states 12/24 V AC or DC power; each input and output's role is configured according to the project.
Local EVOLUTION unit in an enclosure with power supply and opening tamper protection. The ACIE page presents a 12 V DC 1,5 A charger and a 12 V 7 Ah battery to be provided. IP54 enclosure measuring 265 × 195 × 75 mm; backup duration and contents to be specified in the quote.
Module for creating a new ELA+ bus branch. It is presented in an enclosure with opening tamper protection, measuring 110 × 110 × 48 mm with rating IP40. Power supply 12/24 V AC or DC; bus architecture must be checked for the project.
Internal enrolment reader for registering credentials by presenting them. The official page identifies 125 kHz EM technology and power supplied by the controller. Select this module according to the existing controller and credentials used at the installation.
Internal enrolment reader for learning credentials by presentation, using 13,56 MHz MIFARE technology. Power is provided by the control unit. Select the product reference according to credential technology and the configuration of the control unit to be equipped.
868 MHz rolling code radio receiver with programmable Wiegand or Dataclock communication. The ACIE page describes site code management, reading and writing remote controls, and a wire antenna. Optional antenna AT868 and identifiers must be specified in the quotation.
Hands-free reader for active credentials, with programmable Wiegand and Dataclock outputs. The official page presents it with an antenna, a 90° angled mast and mounting clamp, in a IP54 enclosure. Credentials, reading zone and any additional antennas must be defined in the quote.
868 MHz key-fob radio tag for RF-SMART readers. The ACIE datasheet distinguishes hands-free use, stated at 3 to 6 m, from transmission by pressing the button. Radio environment, reader and any lanyard version must be specified in the quotation.
Manual emergency door release with deformable membrane, presented with two contacts. The official data sheet states maximum switching capacity of 30 V and 2 A, IP21 rating and dimensions of 87,5 × 87,5 × 56,5 mm. Define connection according to the locking device.
Emergency release call point with three NO/NC contacts, visual and audible signalling. The ACIE datasheet describes green standby lighting, flashing red on activation, a protective cover and front reset. Surface mounting; electrical configuration to be specified in the quotation.
Touchless proximity exit control, with stainless steel faceplate and surface-mount housing. The manufacturer specifies adjustable detection from 3 to 12 cm, adjustable timer, two-colour indicator and NO/NC relay output. 12 V DC power supply and IP65 protection.
Supplementary power supply enclosure for indoor installation, with key lock and mains, 12 V and battery indicators. The ACIE page specifies a 12 V DC 5 A charger and a 12 V 17 Ah battery to be provided. Electrical requirements and backup duration must be sized for the project.
Indoor supplementary power supply enclosure with key lock and mains, 24 V and battery indicators. The manufacturer states a 24 V DC, 2,5 A charger and provision for two 12 V 7 Ah batteries. Required capacity depends on connected equipment.
24 V charger enclosure for indoor installation, with key lock, mains and battery indicators, and mains/battery fault outputs. The ACIE page presents an enclosure measuring 395 × 285 × 165 mm. Batteries and required power must be specified during project assessment.
Battery-powered radio keypad for code-operated commands. The catalogue specifies twelve users and three codes per channel. The necessary radio receiver and remote controls must be provided separately; integration of transmitters from other manufacturers requires assessment with the manufacturer.
Transmitter and receiver set for radio transmission of Wiegand or Dataclock reader data. It enables assessment of a connection without a bus cable between the reader and its controller. The catalogue describes 12 V DC supply and a IP54 enclosure.
ACIE products and product pages.
Reference documents.
ACIE - Catalogue
Access control, readers and locking
Compilation p. 1230–1306 · original PDF 43,7 MBDocument links and resources (4)
Product references, equipment and availability to be confirmed for your project.
Manufacturer documents remain in their original language.
